IDUB-80Dome Light with coaxial light – IDUB series
| Model | IDUB-80W | IDUB-80R | IDUB-80B |
|---|---|---|---|
| Product Number | 352-110 | 352-111 | 352-112 |
| Color | ![]() |
![]() |
![]() |
| Color temperature/Peak Wavelength | 5700K typ. | 635nm typ. | 470nm typ. |
| Input Voltage | DC12V | ||
| Power Consumption | 13.2W | ||
| Cable Length | 500mm | ||
| Input Connector | SM connector(SMR-02V-B) | ||
| Polarity | 1:+ 2:- | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 35~85% (non condensing) | ||
| Weight | 200g | ||
| Conformity Standard | ![]() IEC62471 |
||
| RoHS Directive | ![]() |
||
| China RoHS | ![]() |
||
| Cables | |||
| Controllers |
Check the output voltage of the compatible power supply. |
||
IDUB-60
IDUB-60Dome Light with coaxial light – IDUB series
| Model | IDUB-60W | IDUB-60R | IDUB-60B |
|---|---|---|---|
| Product Number | 352-100 | 352-101 | 352-102 |
| Color | ![]() |
![]() |
![]() |
| Color temperature/Peak Wavelength | 5700K typ. | 635nm typ. | 470nm typ. |
| Input Voltage | DC12V | ||
| Power Consumption | 10.7W | ||
| Cable Length | 500mm | ||
| Input Connector | SM connector(SMR-02V-B) | ||
| Polarity | 1:+ 2:- | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 35~85% (non condensing) | ||
| Weight | 180g | ||
| Conformity Standard | ![]() IEC62471 |
||
| RoHS Directive | ![]() |
||
| China RoHS | ![]() |
||
| Cables | |||
| Controllers |
Check the output voltage of the compatible power supply. |
||
IDUB series
Dome Light with coaxial lightIDUB series
Uniform dome irradiation with coaxial lighting
IDUB series has integrated mounting Coaxial Lighting with Dome Lighting.
Multi-angle irradiation by Dome Lighting and regular reflection by Coaxial Lighting can uniform irradiation although three-dimensional work.
The Dome Light and Pseudo Coaxial Light have respective circuits, and the light can be controlled independently.
| Model | Input Voltage | Color | External dimensions (lateral direction/longitudinal direction/height) |
Lighting opening (Dome part Camera side / Work side) |
|---|---|---|---|---|
| IDUB-60 | DC12V | ![]() ![]() ![]() |
66 / 83.6 / 52.8 | □15 / φ30 |
| IDUB-80 | DC12V | ![]() ![]() ![]() |
85 / 90.5 / 71.5 | □20 / φ47 |
| IDUB-120 | DC12V | ![]() ![]() ![]() |
124 / 126.5 / 108 | □40 / φ77 |
| IDUB-150 | DC12V | ![]() ![]() ![]() |
154 / 156.5 / 131 | □50 / φ107 |
| IDUB-220 | DC12V | ![]() ![]() ![]() |
223 / 225.5 / 169.8 | □50 / φ176 |
| IDUB-60_HV | DC24V | ![]() ![]() ![]() |
66 / 83.6 / 52.8 | □15 / φ30 |
| IDUB-80_HV | DC24V | ![]() ![]() ![]() |
85 / 90.5 / 71.5 | □20 / φ47 |
| IDUB-120_HV | DC24V | ![]() ![]() ![]() |
124 / 126.5 / 108 | □40 / φ77 |
| IDUB-150_HV | DC24V | ![]() ![]() ![]() |
154 / 156.5 / 131 | □50 / φ107 |
| IDUB-220_HV | DC24V | ![]() ![]() ![]() |
223 / 225.5 / 169.8 | □50 / φ176 |
IDGB-150M8PG-24-TP-T-L
IDGB-150M8PG-24-TP-T-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-150M8-24-TP-T
| Model | IDGB-150M8PG-24-TP-T-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 144W |
| Input Voltage | DC24V |
| Input Current | 6.25A(Max) |
| Rated Output Voltage | DC24V |
| Rated Output Current | 6A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-150M4PG-24-TP-T-L
IDGB-150M4PG-24-TP-T-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-150M4-24-TP-T
| Model | IDGB-150M4PG-24-TP-T-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 4ch |
| Output Power | 144W |
| Input Voltage | DC24V |
| Input Current | 6.25A(Max) |
| Rated Output Voltage | DC24V |
| Rated Output Current | 6A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2PG-24-TP-T-L
IDGB-50M2PG-24-TP-T-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M2-24-TP-T
| Model | IDGB-50M2PG-24-TP-T-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 46W |
| Input Voltage | DC24V |
| Input Current | 2.08A(Max) |
| Rated Output Voltage | DC24V |
| Rated Output Current | 1.9A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 700g |
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8PG-24-TP-L
IDGB-100M8PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M8-24
| Model | IDGB-100M8PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4PG-24-TP-L
IDGB-100M4PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M4-24
| Model | IDGB-100M4PG-24-TP-L |
|---|---|
| Product Number | 457-350 |
| Channel numbers | 4ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2PG-24-TP-L
IDGB-100M2PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M2-24
| Model | IDGB-100M2PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8PG-24-TP-L
IDGB-50M8PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M8-24
| Model | IDGB-50M8PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 2.1A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4PG-24-TP-L
IDGB-50M4PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M4-24
| Model | IDGB-50M4PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 4ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 2.1A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2PG-24-TP-L
IDGB-50M2PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M4-24
| Model | IDGB-50M2PG-24-TP-L |
|---|---|
| Product Number | 457-241 |
| Channel numbers | 2ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8PG-24-TP-L
IDGB-30M8PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M8-24
| Model | IDGB-30M8PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 1.3A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4PG-24-TP-L
IDGB-30M4PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M4-24
| Model | IDGB-30M4PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 4ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 1.3A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2PG-24-TP-L
IDGB-30M2PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M2-24
| Model | IDGB-30M2PG-24-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC24V |
| Rated Output Current | 1.3A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-03V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 700g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8PG-TP-L
IDGB-100M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M8
| Model | IDGB-100M8PG-TP-L |
|---|---|
| Product Number | 456-361 |
| Channel numbers | 8ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 8.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4PG-TP-L
IDGB-100M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M4
| Model | IDGB-100M4PG-TP-L |
|---|---|
| Product Number | 456-352 |
| Channel numbers | 4ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 8.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2PG-TP-L
IDGB-100M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M2
| Model | IDGB-100M2PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 100W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 8.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1300g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8PG-TP-L
IDGB-50M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M8
| Model | IDGB-50M8PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4PG-TP-L
IDGB-50M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M4
| Model | IDGB-50M4PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 4ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2PG-TP-L
IDGB-50M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M2
| Model | IDGB-50M2PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 50W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 4.17A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8PG-TP-L
IDGB-30M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M8
| Model | IDGB-30M8PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 8ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 2.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4PG-TP-L
IDGB-30M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M4
| Model | IDGB-30M4PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 4ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 2.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 1000g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2PG-TP-L
IDGB-30M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M2
| Model | IDGB-30M2PG-TP-L |
|---|---|
| Product Number | T.B.D. |
| Channel numbers | 2ch |
| Output Power | 30W |
| Input Voltage | AC100~240V |
| Operating Frequency | 50/60Hz |
| Rated Output Voltage | DC12V |
| Rated Output Current | 2.5A |
| Light Control System | PWM approx. 125kHz |
| External Control | External On/Off Control |
| Internal Light Control Method | 8-bit digital(256 levels) |
| External Light Control Method | Ethernet communication ※ |
| Output Connector | SM connector(SMP-02V-BC) |
| Operating Temperature | 0~+40℃ |
| Operating Humidity | 20~70% (non condensing) |
| Weight | 700g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
| China RoHS | ![]() |
| Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-PG-L series
Programable Digital PWM ControllerIDGB-PG-L series
Programming mode function is added as a new function
IDGB-L series power supply with programming mode function.
A single ON signal controls the number outputs and sequence that will be turned on.
Two types of lighting mode, level mode and edge mode, can be selected.
The lighting sequence, dimming, and light emitting time of up to 8 channels x 4 patterns can be set and saved.
The man-hours for line adjustment can be reduced by using the programming mode function which made it easy to switch the control depending on the inspection contents and inspection objects.
There are two differences in specifications from the IDGB-L series.
- The variable output range may change slightly, resulting in variations in the output between the dimming range [0 to 15] and [245 to 255].
- Auto MDI / MDI-X function will not be installed
Dec. 28, 2022 End of production
Replacement:IDGC series
| Model | Output Power | Channel numbers | Input Voltage | Output Voltage | External Light Control |
|---|---|---|---|---|---|
| IDGB-30M2PG-TP-L | 30W | 2CH | AC100~240V | DC12V | ○ |
| IDGB-30M4PG-TP-L | 30W | 4CH | AC100~240V | DC12V | ○ |
| IDGB-30M8PG-TP-L | 30W | 8CH | AC100~240V | DC12V | ○ |
| IDGB-50M2PG-TP-L | 50W | 2CH | AC100~240V | DC12V | ○ |
| IDGB-50M4PG-TP-L | 50W | 4CH | AC100~240V | DC12V | ○ |
| IDGB-50M8PG-TP-L | 50W | 8CH | AC100~240V | DC12V | ○ |
| IDGB-100M2PG-TP-L | 100W | 2CH | AC100~240V | DC12V | ○ |
| IDGB-100M4PG-TP-L | 100W | 4CH | AC100~240V | DC12V | ○ |
| IDGB-100M8PG-TP-L | 100W | 8CH | AC100~240V | DC12V | ○ |
| IDGB-30M2PG-24-TP-L | 30W | 2CH | AC100~240V | DC24V | ○ |
| IDGB-30M4PG-24-TP-L | 30W | 4CH | AC100~240V | DC24V | ○ |
| IDGB-30M8PG-24-TP-L | 30W | 8CH | AC100~240V | DC24V | ○ |
| IDGB-50M2PG-24-TP-L | 50W | 2CH | AC100~240V | DC24V | ○ |
| IDGB-50M4PG-24-TP-L | 50W | 4CH | AC100~240V | DC24V | ○ |
| IDGB-50M8PG-24-TP-L | 50W | 8CH | AC100~240V | DC24V | ○ |
| IDGB-100M2PG-24-TP-L | 100W | 2CH | AC100~240V | DC24V | ○ |
| IDGB-100M4PG-24-TP-L | 100W | 4CH | AC100~240V | DC24V | ○ |
| IDGB-100M8PG-24-TP-L | 100W | 8CH | AC100~240V | DC24V | ○ |
| IDGB-50M2PG-24-TP-T-L | 46W | 2CH | DC24V | DC24V | ○ |
| IDGB-150M4PG-24-TP-T-L | 144W | 4CH | DC24V | DC24V | ○ |
| IDGB-150M8PG-24-TP-T-L | 144W | 8CH | DC24V | DC24V | ○ |
Programing mode
>
Sample application that supports configuration
Easy setting of dimming, lighting sequence, flash duration, etc., with one click.
>
Introduction of application programming examples
No specialized knowledge is required by PLC control. The setting status can be understood at a glance.
8 split ring lighting
>
Multiple lighting (backlight → horizontal ring → coaxial incident lighting)
>
IDGB-150M8-24-_-T-L
IDGB-150M8-24-_-T-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-150M8-24-TP-T
| Model | IDGB-150M8-24-TP/PI-T-L | IDGB-150M8-24-S2/PI-T-L | IDGB-150M8-24-S4/VI-T-L |
|---|---|---|---|
| Product Number | 459-006 | T.B.D. | T.B.D. |
| Channel numbers | 8ch | ||
| Output Power | 144W | ||
| Input Voltage | DC24V | ||
| Input Current | 6.25A(Max) | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1000g | ||
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-150M4-24-_-T-L
IDGB-150M4-24-_-T-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-150M4-24-TP-T
| Model | IDGB-150M4-24-TP/PI-T-L | IDGB-150M4-24-S2/PI-T-L | IDGB-150M4-24-S4/VI-T-L |
|---|---|---|---|
| Product Number | 459-003 | T.B.D. | T.B.D. |
| Channel numbers | 4ch | ||
| Output Power | 144W | ||
| Input Voltage | DC24V | ||
| Input Current | 6.25A(Max) | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1000g | ||
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2-24-_-T-L
IDGB-50M2-24-_-T-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M2-24-TP-T
| Model | IDGB-50M2-24-TP/PI-T-L | IDGB-50M2-24-S2/PI-T-L | IDGB-50M2-24-S4/VI-T-L |
|---|---|---|---|
| Product Number | 459-000 | 459-001 | 459-002 |
| Channel numbers | 2ch | ||
| Output Power | 46W | ||
| Input Voltage | DC24V | ||
| Input Current | 2.08A(Max) | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 700g | ||
| Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8-24-_-L
IDGB-100M8-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M8-24
| Model | IDGB-100M8-24-TP/PI-L | IDGB-100M8-24-S2/PI-L | IDGB-100M8-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-030 | T.B.D. | T.B.D. |
| Channel numbers | 8ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4-24-_-L
IDGB-100M4-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M4-24
| Model | IDGB-100M4-24-TP/PI-L | IDGB-100M4-24-S2/PI-L | IDGB-100M4-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-027 | T.B.D. | 457-029 |
| Channel numbers | 4ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| RoHS Directive | ![]() |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2-24-_-L
IDGB-100M2-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M2-24
| Model | IDGB-100M2-24-TP/PI-L | IDGB-100M2-24-S2/PI-L | IDGB-100M2-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-024 | T.B.D. | T.B.D. |
| Channel numbers | 2ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8-24-_-L
IDGB-50M8-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M8-24
| Model | IDGB-50M8-24-TP/PI-L | IDGB-50M8-24-S2/PI-L | IDGB-50M8-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-018 | T.B.D. | T.B.D. |
| Channel numbers | 8ch | ||
| Output Power | 50W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1200g | 1050g | 1200g |
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| RoHS Directive | ![]() |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4-24-_-L
IDGB-50M4-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M5-24
| Model | IDGB-50M4-24-TP/PI-L | IDGB-50M4-24-S2/PI-L | IDGB-50M4-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-015 | T.B.D. | T.B.D. |
| Channel numbers | 4ch | ||
| Output Power | 50W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1200g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2-24-_-L
IDGB-50M2-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-50M2-24
| Model | IDGB-50M2-24-TP/PI-L | IDGB-50M2-24-S2/PI-L | IDGB-50M2-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-012 | T.B.D. | 457-014 |
| Channel numbers | 2ch | ||
| Output Power | 50W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1200g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8-24-_-L
IDGB-30M8-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M8-24
| Model | IDGB-30M8-24-TP/PI-L | IDGB-30M8-24-S2/PI-L | IDGB-30M8-24-S4/VI-L |
|---|---|---|---|
| Product Number | T.B.D. | T.B.D. | T.B.D. |
| Channel numbers | 8ch | ||
| Output Power | 30W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1000g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4-24-_-L
IDGB-30M4-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M4-24
| Model | IDGB-30M4-24-TP/PI-L | IDGB-30M4-24-S2/PI-L | IDGB-30M4-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-003 | T.B.D. | T.B.D. |
| Channel numbers | 4ch | ||
| Output Power | 30W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1000g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2-24-_-L
IDGB-30M2-24-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-30M2-24
| Model | IDGB-30M2-24-TP/PI-L | IDGB-30M2-24-S2/PI-L | IDGB-30M2-24-S4/VI-L |
|---|---|---|---|
| Product Number | 457-000 | 457-001 | T.B.D. |
| Channel numbers | 2ch | ||
| Output Power | 30W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC24V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-03V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 700g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8-_-L
IDGB-100M8-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M8
| Model | IDGB-100M8-TP/PI-L | IDGB-100M8-S2/PI-L | IDGB-100M8-S4/VI-L |
|---|---|---|---|
| Product Number | 456-030 | T.B.D. | 456-032 |
| Channel numbers | 8ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC12V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-02V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4-_-L
IDGB-100M4-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M4
| Model | IDGB-100M4-TP/PI-L | IDGB-100M4-S2/PI-L | IDGB-100M4-S4/VI-L |
|---|---|---|---|
| Product Number | 456-027 | T.B.D. | 456-029 |
| Channel numbers | 4ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC12V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-02V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2-_-L
IDGB-100M2-_-LDigital PWM Controller – IDGB-L series
Dec. 28, 2022 End of production
Replacement:IDGC-100M2
| Model | IDGB-100M2-TP/PI-L | IDGB-100M2-S2/PI-L | IDGB-100M2-S4/VI-L |
|---|---|---|---|
| Product Number | 456-024 | T.B.D. | T.B.D. |
| Channel numbers | 2ch | ||
| Output Power | 100W | ||
| Input Voltage | AC100~240V | ||
| Operating Frequency | 50/60Hz | ||
| Rated Output Voltage | DC12V | ||
| Light Control System | PWM approx. 125kHz | ||
| External Control | External On/Off Control | ||
| Internal Light Control Method | 8-bit digital(256 levels) | ||
| External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
| Output Connector | SM connector(SMP-02V-BC) | ||
| Operating Temperature | 0~+40℃ | ||
| Operating Humidity | 20~70% (non condensing) | ||
| Weight | 1300g | ||
| Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
| China RoHS | ![]() |
||
| Options | |||
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.