IDGB-30M2PG-24-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M2-24
Model | IDGB-30M2PG-24-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 2ch |
Output Power | 30W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC24V |
Rated Output Current | 1.3A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-03V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 700g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8PG-TP-L
IDGB-100M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M8
Model | IDGB-100M8PG-TP-L |
---|---|
Product Number | 456-361 |
Channel numbers | 8ch |
Output Power | 100W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 8.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1300g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4PG-TP-L
IDGB-100M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M4
Model | IDGB-100M4PG-TP-L |
---|---|
Product Number | 456-352 |
Channel numbers | 4ch |
Output Power | 100W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 8.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1300g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2PG-TP-L
IDGB-100M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M2
Model | IDGB-100M2PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 2ch |
Output Power | 100W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 8.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1300g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8PG-TP-L
IDGB-50M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M8
Model | IDGB-50M8PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 8ch |
Output Power | 50W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 4.17A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1200g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4PG-TP-L
IDGB-50M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M4
Model | IDGB-50M4PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 4ch |
Output Power | 50W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 4.17A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1200g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2PG-TP-L
IDGB-50M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M2
Model | IDGB-50M2PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 2ch |
Output Power | 50W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 4.17A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1200g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8PG-TP-L
IDGB-30M8PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M8
Model | IDGB-30M8PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 8ch |
Output Power | 30W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 2.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1000g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4PG-TP-L
IDGB-30M4PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M4
Model | IDGB-30M4PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 4ch |
Output Power | 30W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 2.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 1000g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2PG-TP-L
IDGB-30M2PG-TP-LProgramable Digital PWM Controller – IDGB-PG-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M2
Model | IDGB-30M2PG-TP-L |
---|---|
Product Number | T.B.D. |
Channel numbers | 2ch |
Output Power | 30W |
Input Voltage | AC100~240V |
Operating Frequency | 50/60Hz |
Rated Output Voltage | DC12V |
Rated Output Current | 2.5A |
Light Control System | PWM approx. 125kHz |
External Control | External On/Off Control |
Internal Light Control Method | 8-bit digital(256 levels) |
External Light Control Method | Ethernet communication ※ |
Output Connector | SM connector(SMP-02V-BC) |
Operating Temperature | 0~+40℃ |
Operating Humidity | 20~70% (non condensing) |
Weight | 700g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
China RoHS | ![]() |
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-PG-L series
Programable Digital PWM ControllerIDGB-PG-L series
Programming mode function is added as a new function
IDGB-L series power supply with programming mode function.
A single ON signal controls the number outputs and sequence that will be turned on.
Two types of lighting mode, level mode and edge mode, can be selected.
The lighting sequence, dimming, and light emitting time of up to 8 channels x 4 patterns can be set and saved.
The man-hours for line adjustment can be reduced by using the programming mode function which made it easy to switch the control depending on the inspection contents and inspection objects.
There are two differences in specifications from the IDGB-L series.
- The variable output range may change slightly, resulting in variations in the output between the dimming range [0 to 15] and [245 to 255].
- Auto MDI / MDI-X function will not be installed
Dec. 28, 2022 End of production
Replacement:IDGC series

Model | Output Power | Channel numbers | Input Voltage | Output Voltage | External Light Control |
---|---|---|---|---|---|
IDGB-30M2PG-TP-L | 30W | 2CH | AC100~240V | DC12V | ○ |
IDGB-30M4PG-TP-L | 30W | 4CH | AC100~240V | DC12V | ○ |
IDGB-30M8PG-TP-L | 30W | 8CH | AC100~240V | DC12V | ○ |
IDGB-50M2PG-TP-L | 50W | 2CH | AC100~240V | DC12V | ○ |
IDGB-50M4PG-TP-L | 50W | 4CH | AC100~240V | DC12V | ○ |
IDGB-50M8PG-TP-L | 50W | 8CH | AC100~240V | DC12V | ○ |
IDGB-100M2PG-TP-L | 100W | 2CH | AC100~240V | DC12V | ○ |
IDGB-100M4PG-TP-L | 100W | 4CH | AC100~240V | DC12V | ○ |
IDGB-100M8PG-TP-L | 100W | 8CH | AC100~240V | DC12V | ○ |
IDGB-30M2PG-24-TP-L | 30W | 2CH | AC100~240V | DC24V | ○ |
IDGB-30M4PG-24-TP-L | 30W | 4CH | AC100~240V | DC24V | ○ |
IDGB-30M8PG-24-TP-L | 30W | 8CH | AC100~240V | DC24V | ○ |
IDGB-50M2PG-24-TP-L | 50W | 2CH | AC100~240V | DC24V | ○ |
IDGB-50M4PG-24-TP-L | 50W | 4CH | AC100~240V | DC24V | ○ |
IDGB-50M8PG-24-TP-L | 50W | 8CH | AC100~240V | DC24V | ○ |
IDGB-100M2PG-24-TP-L | 100W | 2CH | AC100~240V | DC24V | ○ |
IDGB-100M4PG-24-TP-L | 100W | 4CH | AC100~240V | DC24V | ○ |
IDGB-100M8PG-24-TP-L | 100W | 8CH | AC100~240V | DC24V | ○ |
IDGB-50M2PG-24-TP-T-L | 46W | 2CH | DC24V | DC24V | ○ |
IDGB-150M4PG-24-TP-T-L | 144W | 4CH | DC24V | DC24V | ○ |
IDGB-150M8PG-24-TP-T-L | 144W | 8CH | DC24V | DC24V | ○ |
Programing mode
>
Sample application that supports configuration
Easy setting of dimming, lighting sequence, flash duration, etc., with one click.
>
Introduction of application programming examples
No specialized knowledge is required by PLC control. The setting status can be understood at a glance.
8 split ring lighting
>
Multiple lighting (backlight → horizontal ring → coaxial incident lighting)
>
IDGB-150M8-24-_-T-L
IDGB-150M8-24-_-T-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-150M8-24-TP-T
Model | IDGB-150M8-24-TP/PI-T-L | IDGB-150M8-24-S2/PI-T-L | IDGB-150M8-24-S4/VI-T-L |
---|---|---|---|
Product Number | 459-006 | T.B.D. | T.B.D. |
Channel numbers | 8ch | ||
Output Power | 144W | ||
Input Voltage | DC24V | ||
Input Current | 6.25A(Max) | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-150M4-24-_-T-L
IDGB-150M4-24-_-T-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-150M4-24-TP-T
Model | IDGB-150M4-24-TP/PI-T-L | IDGB-150M4-24-S2/PI-T-L | IDGB-150M4-24-S4/VI-T-L |
---|---|---|---|
Product Number | 459-003 | T.B.D. | T.B.D. |
Channel numbers | 4ch | ||
Output Power | 144W | ||
Input Voltage | DC24V | ||
Input Current | 6.25A(Max) | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2-24-_-T-L
IDGB-50M2-24-_-T-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M2-24-TP-T
Model | IDGB-50M2-24-TP/PI-T-L | IDGB-50M2-24-S2/PI-T-L | IDGB-50M2-24-S4/VI-T-L |
---|---|---|---|
Product Number | 459-000 | 459-001 | 459-002 |
Channel numbers | 2ch | ||
Output Power | 46W | ||
Input Voltage | DC24V | ||
Input Current | 2.08A(Max) | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 700g | ||
Conformity Standard | ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8-24-_-L
IDGB-100M8-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M8-24
Model | IDGB-100M8-24-TP/PI-L | IDGB-100M8-24-S2/PI-L | IDGB-100M8-24-S4/VI-L |
---|---|---|---|
Product Number | 457-030 | T.B.D. | T.B.D. |
Channel numbers | 8ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4-24-_-L
IDGB-100M4-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M4-24
Model | IDGB-100M4-24-TP/PI-L | IDGB-100M4-24-S2/PI-L | IDGB-100M4-24-S4/VI-L |
---|---|---|---|
Product Number | 457-027 | T.B.D. | 457-029 |
Channel numbers | 4ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
RoHS Directive | ![]() |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2-24-_-L
IDGB-100M2-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M2-24
Model | IDGB-100M2-24-TP/PI-L | IDGB-100M2-24-S2/PI-L | IDGB-100M2-24-S4/VI-L |
---|---|---|---|
Product Number | 457-024 | T.B.D. | T.B.D. |
Channel numbers | 2ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8-24-_-L
IDGB-50M8-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M8-24
Model | IDGB-50M8-24-TP/PI-L | IDGB-50M8-24-S2/PI-L | IDGB-50M8-24-S4/VI-L |
---|---|---|---|
Product Number | 457-018 | T.B.D. | T.B.D. |
Channel numbers | 8ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | 1050g | 1200g |
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
RoHS Directive | ![]() |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4-24-_-L
IDGB-50M4-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M5-24
Model | IDGB-50M4-24-TP/PI-L | IDGB-50M4-24-S2/PI-L | IDGB-50M4-24-S4/VI-L |
---|---|---|---|
Product Number | 457-015 | T.B.D. | T.B.D. |
Channel numbers | 4ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2-24-_-L
IDGB-50M2-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M2-24
Model | IDGB-50M2-24-TP/PI-L | IDGB-50M2-24-S2/PI-L | IDGB-50M2-24-S4/VI-L |
---|---|---|---|
Product Number | 457-012 | T.B.D. | 457-014 |
Channel numbers | 2ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8-24-_-L
IDGB-30M8-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M8-24
Model | IDGB-30M8-24-TP/PI-L | IDGB-30M8-24-S2/PI-L | IDGB-30M8-24-S4/VI-L |
---|---|---|---|
Product Number | T.B.D. | T.B.D. | T.B.D. |
Channel numbers | 8ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4-24-_-L
IDGB-30M4-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M4-24
Model | IDGB-30M4-24-TP/PI-L | IDGB-30M4-24-S2/PI-L | IDGB-30M4-24-S4/VI-L |
---|---|---|---|
Product Number | 457-003 | T.B.D. | T.B.D. |
Channel numbers | 4ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2-24-_-L
IDGB-30M2-24-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M2-24
Model | IDGB-30M2-24-TP/PI-L | IDGB-30M2-24-S2/PI-L | IDGB-30M2-24-S4/VI-L |
---|---|---|---|
Product Number | 457-000 | 457-001 | T.B.D. |
Channel numbers | 2ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC24V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-03V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 700g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M8-_-L
IDGB-100M8-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M8
Model | IDGB-100M8-TP/PI-L | IDGB-100M8-S2/PI-L | IDGB-100M8-S4/VI-L |
---|---|---|---|
Product Number | 456-030 | T.B.D. | 456-032 |
Channel numbers | 8ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M4-_-L
IDGB-100M4-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M4
Model | IDGB-100M4-TP/PI-L | IDGB-100M4-S2/PI-L | IDGB-100M4-S4/VI-L |
---|---|---|---|
Product Number | 456-027 | T.B.D. | 456-029 |
Channel numbers | 4ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-100M2-_-L
IDGB-100M2-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-100M2
Model | IDGB-100M2-TP/PI-L | IDGB-100M2-S2/PI-L | IDGB-100M2-S4/VI-L |
---|---|---|---|
Product Number | 456-024 | T.B.D. | T.B.D. |
Channel numbers | 2ch | ||
Output Power | 100W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1300g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M8-_-L
IDGB-50M8-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M8
Model | IDGB-50M8-TP/PI-L | IDGB-50M8-S2/PI-L | IDGB-50M8-S4/VI-L |
---|---|---|---|
Product Number | 456-018 | T.B.D. | 456-020 |
Channel numbers | 8ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M4-_-L
IDGB-50M4-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M4
Model | IDGB-50M4-TP/PI-L | IDGB-50M4-S2/PI-L | IDGB-50M4-S4/VI-L |
---|---|---|---|
Product Number | 456-015 | T.B.D. | 456-017 |
Channel numbers | 4ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-50M2-_-L
IDGB-50M2-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-50M2
Model | IDGB-50M2-TP/PI-L | IDGB-50M2-S2/PI-L | IDGB-50M2-S4/VI-L |
---|---|---|---|
Product Number | 456-012 | 456-013 | 456-014 |
Channel numbers | 2ch | ||
Output Power | 50W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1200g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M8-_-L
IDGB-30M8-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M8
Model | IDGB-30M8-TP/PI-L | IDGB-30M8-S2/PI-L | IDGB-30M8-S4/VI-L |
---|---|---|---|
Product Number | 456-006 | 456-007 | T.B.D. |
Channel numbers | 8ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M4-_-L
IDGB-30M4-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M4
Model | IDGB-30M4-TP/PI-L | IDGB-30M4-S2/PI-L | IDGB-30M4-S4/VI-L |
---|---|---|---|
Product Number | 456-003 | 456-004 | 456-005 |
Channel numbers | 4ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 1000g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-30M2-_-L
IDGB-30M2-_-LDigital PWM Controller – IDGB-L series

Dec. 28, 2022 End of production
Replacement:IDGC-30M2
Model | IDGB-30M2-TP/PI-L | IDGB-30M2-S2/PI-L | IDGB-30M2-S4/VI-L |
---|---|---|---|
Product Number | 456-000 | 456-001 | 456-002 |
Channel numbers | 2ch | ||
Output Power | 30W | ||
Input Voltage | AC100~240V | ||
Operating Frequency | 50/60Hz | ||
Rated Output Voltage | DC12V | ||
Light Control System | PWM approx. 125kHz | ||
External Control | External On/Off Control | ||
Internal Light Control Method | 8-bit digital(256 levels) | ||
External Light Control Method | Ethernet communication/8 bit parallel communication switch ※ | RS-232C communication/8 bit parallel communication switch | RS-485 communication/Analog 0-5V switch |
Output Connector | SM connector(SMP-02V-BC) | ||
Operating Temperature | 0~+40℃ | ||
Operating Humidity | 20~70% (non condensing) | ||
Weight | 700g | ||
Conformity Standard | ![]() ![]() CE(EN61010-1,EN55011,EN61000-6-2) |
||
China RoHS | ![]() |
||
Options |
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
IDGB-L series
Digital PWM Controller [substitute]IDGB-L series
IDGB series, limited-time substitute
Due to the worldwide shortage of semiconductors and electronic components, the delivery time of components has become noticeably longer, and it is difficult to procure components used in controller., We have released a product with limited functions of the IDGB controller as a substitute.
* Orders for IDGB controller will resume as soon as parts procurement returns to normal.
There are two differences in specifications from the IDGB series.
- The variable output range may change slightly, causing variations in the output between the dimming range [0 to 15] and [245 to 255].
* There is a variation in output between [0 to 10] and [250 to 255] in the dimming range of the current product. - Auto MDI / MDI-X function will not be installed
Other than the above, there is no difference in specifications between the standard product and the alternative product. P>
Dec. 28, 2022 End of production
Replacement:IDGC series

Model | Output Power |
Channel numbers |
Input Voltage |
Output Voltage |
External Light Control |
---|---|---|---|---|---|
IDGB-30M2-_-L | 30W | 2CH | AC100~240V | DC12V | ○ |
IDGB-30M4-_-L | 30W | 4CH | AC100~240V | DC12V | ○ |
IDGB-30M8-_-L | 30W | 8CH | AC100~240V | DC12V | ○ |
IDGB-50M2-_-L | 50W | 2CH | AC100~240V | DC12V | ○ |
IDGB-50M4-_-L | 50W | 4CH | AC100~240V | DC12V | ○ |
IDGB-50M8-_-L | 50W | 8CH | AC100~240V | DC12V | ○ |
IDGB-100M2-_-L | 100W | 2CH | AC100~240V | DC12V | ○ |
IDGB-100M4-_-L | 100W | 4CH | AC100~240V | DC12V | ○ |
IDGB-100M8-_-L | 100W | 8CH | AC100~240V | DC12V | ○ |
IDGB-30M2-24-_-L | 30W | 2CH | AC100~240V | DC24V | ○ |
IDGB-30M4-24-_-L | 30W | 4CH | AC100~240V | DC24V | ○ |
IDGB-30M8-24-_-L | 30W | 8CH | AC100~240V | DC24V | ○ |
IDGB-50M2-24-_-L | 50W | 2CH | AC100~240V | DC24V | ○ |
IDGB-50M4-24-_-L | 50W | 4CH | AC100~240V | DC24V | ○ |
IDGB-50M8-24-_-L | 50W | 8CH | AC100~240V | DC24V | ○ |
IDGB-100M2-24-_-L | 100W | 2CH | AC100~240V | DC24V | ○ |
IDGB-100M4-24-_-L | 100W | 4CH | AC100~240V | DC24V | ○ |
IDGB-100M8-24-_-L | 100W | 8CH | AC100~240V | DC24V | ○ |
IDGB-50M2-24-_-T-L | 46W | 2CH | DC24V | DC24V | ○ |
IDGB-150M4-24-_-T-L | 144W | 4CH | DC24V | DC24V | ○ |
IDGB-150M8-24-_-T-L | 144W | 8CH | DC24V | DC24V | ○ |
A Total Lineup of 63 Various Models
A total lineup of 63 various models with two kinds of output voltage of DC12V/24V, three capacities of 30W/50W/100W with three channel choices of 2CH/4CH/8CH each.
The various selections give you the best choice of the power supply depending on light combination and the environment.
Adjustable to DIN Rall Installation for 63 Sizes
Fullfiling External Control Function
The three lineup of “LAN communication/8 bit parallel communication”switch, “RS-232C communication/8 bit parallel communication” switch, “RS-485 communication/Analog 0-5V” switch are available as standard.
External light control can be chosen for your network environment.
※ If the terminal such as PC / PLC or HUB does not have the Auto MDI / MDI-X function, it is necessary to use a Straight Cable or Crossover Cable for the LAN cable.
If your PC or HUB has an Auto MDI / MDI-X function, you can use either a Straight Cable or Crossover Cable.
External ON/OFF Signal and Inverting Function of Lighting Output
The conventional products had a lighting fluctuation due to the a synchronism of an external ON/OFF signal and inner PWM cycle.
However, the PWM cycle of this product synchronizes with the external ON/OFF signal so it has no lighting fluctuation.
Various External ON/OFF Functions
With the external ON/OFF mode, the “High Mode” which enables the lighting to be turned off with the signal and the “Low Mode” which enavles the lighting to be turned on with the signal are switchable.
External ON/OFF type has “Normal type”, “Repeat type” which keeps lighting with one trigger, and “Single type” which turns the light on for one cycle with one trigger.
In all patterns, the delay time from the external ON / OFF signal to lighting can be set in the range of 0 to 9,999 μS for each channel (delay control).
The Digital Display with Good Visibility Makes Chacking the Set Value Easier
IHRB-220_HVS
IHRB-220_HVSLightweight NEO Ring illumination – IHRB series

Model | IHRB-220DWHVS | IHRB-220AWHVS | IHRB-220RHVS | IHRB-220BHVS | IHRB-220 IR-850HVS |
---|---|---|---|---|---|
Product Number | 340-769 | 340-767 | 340-766 | 340-765 | 340-768 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC24V | ||||
Power Consumption | 28.5W | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector (SMR-03V-B) | ||||
Polarity | 1:+ 2:NC 3:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 470g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-150_HVS
IHRB-150_HVSLightweight NEO Ring illumination – IHRB series

Model | IHRB-150DWHVS | IHRB-150AWHVS | IHRB-150RHVS | IHRB-150BHVS | IHRB-150 IR-850HVS |
---|---|---|---|---|---|
Product Number | 340-759 | 340-757 | 340-756 | 340-755 | 340-758 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC24V | ||||
Power Consumption | 18W | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector (SMR-03V-B) | ||||
Polarity | 1:+ 2:NC 3:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 320g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-120_HVS
IHRB-120_HVSLightweight NEO Ring illumination – IHRB series

Model | IHRB-120DWHVS | IHRB-120AWHVS | IHRB-120RHVS | IHRB-120BHVS | IHRB-120 IR-850HVS |
---|---|---|---|---|---|
Product Number | 340-769 | 340-767 | 340-766 | 340-765 | 340-768 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC24V | ||||
Power Consumption | 13.5W | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector (SMR-03V-B) | ||||
Polarity | 1:+ 2:NC 3:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 265g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-80_HVS
IHRB-80_HVSLightweight NEO Ring illumination – IHRB series

Model | IHRB-80DWHVS | IHRB-80AWHVS | IHRB-80RHVS | IHRB-80BHVS | IHRB-80 IR-850HVS |
---|---|---|---|---|---|
Product Number | 340-739 | 340-737 | 340-736 | 340-735 | 340-738 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC24V | ||||
Power Consumption | 9W | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector (SMR-03V-B) | ||||
Polarity | 1:+ 2:NC 3:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 135g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-60_HVS
IHRB-60_HVSLightweight NEO Ring illumination – IHRB series

Model | IHRB-60DWHVS | IHRB-60AWHVS | IHRB-60RHVS | IHRB-60BHVS | IHRB-60 IR-850HVS |
---|---|---|---|---|---|
Product Number | 340-789 | 340-787 | 340-786 | 340-785 | 340-788 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC24V | ||||
Power Consumption | 6.5W | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector (SMR-03V-B) | ||||
Polarity | 1:+ 2:NC 3:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 105g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-220_S
IHRB-220_SLightweight NEO Ring illumination – IHRB series

Model | IHRB-220DWS | IHRB-220AWS | IHRB-220RS | IHRB-220BS | IHRB-220 IR-850S |
---|---|---|---|---|---|
Product Number | 340-760 | 340-763 | 340-762 | 340-761 | 340-764 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC12V | ||||
Power Consumption | 28.5W | ||||
SAG Setting Value | C3 | FF | |||
Cable Length | 500mm | ||||
Input Connector | SM connector(SMR-02V-B) | ||||
Polarity | 1:+ 2:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 470g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |
IHRB-150_S
IHRB-150_SLightweight NEO Ring illumination – IHRB series

Model | IHRB-150DWS | IHRB-150AWS | IHRB-150RS | IHRB-150BS | IHRB-150 IR-850S |
---|---|---|---|---|---|
Product Number | 340-750 | 340-753 | 340-752 | 340-751 | 340-754 |
Color | ![]() |
![]() |
![]() |
![]() |
![]() |
Color temperature/Peak Wavelength | 5700K typ. | 4900K typ. | 635nm typ. | 465nm typ. | 850nm typ. |
Input Voltage | DC12V | ||||
Power Consumption | 18W | ||||
SAG Setting Value | FF | ||||
Cable Length | 500mm | ||||
Input Connector | SM connector(SMR-02V-B) | ||||
Polarity | 1:+ 2:- | ||||
Operating Temperature | 0~+40℃ | ||||
Operating Humidity | 35~85% (non condensing) | ||||
Weight | 320g | ||||
Conformity Standard | ![]() IEC62471 |
||||
RoHS Directive | ![]() |
||||
China RoHS | ![]() |
||||
Cables | |||||
Controllers |
Check the output voltage of the compatible Controller. |